Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | JGPV |
Model Number : | DF41X-JGPV |
Price : | USD69.9/Set - 559.9/Set |
Payment Terms : | L/C, T/T, Western Union |
Supply Ability : | 1000pcs per month |
Delivery Time : | 14 days |
Ductile Iron Flanged Backflow Preventer
Product introduction:
DF41X Series backflow preventer is a hydraulic control combination
device that strictly limits the one-way flow of water in pipelines.
Its function is to prevent medium backflow in pipelines under any
working conditions, in order to avoid backflow pollution. The
working principle of backflow preventer is to use the medium to
flow through the inlet check valve and reduce pressure due to
mechanical resistance and loss of flow head, so that the pressure
is higher than the pressure in the discharge valve chamber. The
pressure in the upper part of the discharge valve diaphragm is
pressure, and the pressure in the upper part of the diaphragm is
greater than the resistance in the discharge valve chamber and
spring. The discharge valve remains closed, and the medium flows
normally. When the pressure difference between the pressure and the
discharge valve chamber is less than 0.02Mpa, the medium is in a
critical state of backflow. At this time, the pressure in the upper
part of the discharge valve diaphragm is less than the pressure in
the discharge valve chamber and spring, and the discharge valve
automatically opens, discharging the backflow medium out of the
pipe. At the same time, a large amount of air enters the valve
chamber, forming an air partition to prevent medium backflow. When
the pressure difference Automatic shutdown. When the water pressure
in the pipeline network behind the valve rises beyond the water
pressure at the front end of the valve, if the second one-way check
valve is well sealed and the water will not flow back, the drain
valve will close and not release water. When the seal of the second
one-way check valve fails and leaks, the drain valve will open to
drain and release pressure.
Product technical parameter:
Pressure nominal | 1.6MPa | |
Port size | DN40-300mm | |
Strength test standard | 2.4MPa | |
Sealing test standard | 1.76MPa | |
Parts and material | Body | Ductile iron, cast steel, stainless steel |
Bonnet | Ductile iron, cast steel, stainless steel | |
Disc | Cast steel, stainless steel | |
Stem | Bronze, 2Cr13 | |
Diaphragm | NBR | |
Diaphragm plate | Cast steel, stainless steel | |
Spring | Stainless steel | |
Medium application | Water and oil etc non corrosive mediums | |
Working temperature | 0-80℃ | |
Connection | Flange connection |
Product features:
1. DF41X series backflow preventor adopts the principle of pressure
reduction to achieve low resistance, the actual water loss during
normal operation at an economic flow rate is only 1.8-2.5 meters.
2. The backflow preventer has a compact structure and short size.
The two-stage independent check valve has a small flow resistance,
can open and close, and can prevent damage to the valve and
pipeline caused by sudden increase in back pressure. It has a
silent function.
3. The discharge pressure of the drain valve is adjustable, with
little interference from pipeline fluctuations, and reliable
opening and closing.
4. The design of dual membranes can prevent backflow pollution
caused by membrane damage.
5. The structure of the air partition with dual inlet and outlet
channels ensures that the intake and drainage in the partition
chamber do not affect each other, and there is no problem of poor
drainage or poor drainage. It can limit the possibility of pressure
water backflow or siphon backflow.
6. The built-in control pipeline system avoids the danger of
exposed bypass pipes being easily stolen and damaged, and can
prevent people from using them for poisoning and other destructive
activities. It is also aesthetically pleasing to use.
7. Can be tested and repaired online.
![]() |